I-Server Dry Cooler ye-Computing Center Retrofits

I-V-type dry cooler yakhelwe{1}}ukuqeda ukushisa okusebenzayo okuphezulu kuzilungiselelo zezimboni. Ukucushwa kwayo okuhlukile-okumise okwe-V kukhulisa indawo engaphezulu kuyilapho kunciphisa umkhondo, kuyenze ifaneleke ezimbonini ezinendawo elinganiselwe. Yakhiwe ngamafins e-aluminium namashubhu ethusi, inikeza ukumelana nokugqwala okuhle kakhulu kanye ne-thermal conductivity. Idizayini ye-modular ivumela ukukala okulula, ngamayunithi akwazi ukuphatha imithwalo yokushisa ukusuka ku-50 kW ukuya ku-5 MW. Ezitshalweni zamakhemikhali, ipholisa uketshezi lwenqubo (njenge-glycol) ngokwenqaba ukushisa emoyeni osendaweni, iqede isidingo samasistimu okupholisa{9}asekelwe emanzini. Amafeni{11}}esivinini ashintshashintshayo alungisa ukushintsha kwezinga lokushisa, anciphise ukusetshenziswa kwamandla kufika ku-30%. Ngohlaka lwensimbi oluqinile oluqinile nokuvikelwa kwe-IP55, imelana nezindawo ezinokhahlo, iqinisekisa ukusebenza okuqhubekayo ekufakweni kwangaphandle.
Njengoba yakhelwe ukubuyisela kabusha isikhungo sekhompuyutha, le Server Dry Cooler iqinisekisa isikhathi esingu-24/7 esinabalandeli abangasadingeki, izinto ezishisayo - ezishintshwayo, kanye nokunakekelwa okuqagelayo. Ihlanganisa ukusebenza kahle, ukwethembeka, kanye ne-modularity, ibhekana nezinselele zokuqeda ukushisa ezikhungweni zedatha kuyilapho ihambisana nemigomo yokusimama.
Ukucaciswa Okubalulekile
|
Ipharamitha |
Imininingwane |
|
I-Modular Design |
Amamojula angakala (50 kW – 5 MW iyunithi ngayinye) |
|
Uhlobo lwabalandeli |
Okungafuneki, okushisayo - okuguquguqukayo okushintshwayo - kwabalandeli besivinini |
|
Izinto zokwakha |
Izindlu ezikwazi ukumelana nokugqwala -; okusezingeni eliphezulu - indikimba yesishintshi sokushisa |
|
Ukonga Amandla |
Kufika ku-30% ngokushintshashintsha - kwesilawuli sabalandeli |
|
Ibanga Lokuvikela |
IP55 (imelana nezindawo zangaphandle ezinokhahlo) |
Imininingwane Yomkhiqizo
Idizayini Yesakhiwo Nokuqina
◆ Izindlu: Yakhiwe kusukela ebangeni eliphezulu -, insimbi engagqwali -, indawo epholile iqinisekisa ukuqina kwesikhathi eside - ezindaweni zesikhungo sedatha. Ingakwazi ukumelana nokushintshashintsha kwezinga lokushisa, uthuli, nokuchayeka komswakamo okuncane, iyenze ifaneleke kokubili ukufakwa kwangaphakathi nangaphandle.
◆ Amayunithi Emodyuli: Iyunithi ngayinye ye-modular ikala u-800mm (W) × 1200mm (D) × 1500mm (H) futhi inesisindo esingaba ngu-200 kg (ngemojula ngayinye engu-50 kW). Usayizi ohlangene uvumela ukuhlanganiswa okulula ezikhungweni zamakhompiyutha ezikhona, ngisho nalezo ezinendawo elinganiselwe. Amamojula angastakwa noma ahlelwe ngokuhambisana, okuvumela ukukala okungenazihibe njengoba imithwalo yokushisa yesikhungo sedatha ikhula.
Ukusebenza Okushisayo
◆ I-Heat Exchanger Core: Ingqikithi isebenzisa inhlanganisela yamaphiko e-aluminium namashubhu ethusi, okwandisa ukuqhutshwa kokushisa. Ingahlakaza imithwalo yokushisa esukela ku-50 kW kuya ku-5 MW module ngayinye, igcine izinga lokushisa elizinzile leseva (i-18℃- 27℃optimal range) ngesikhathi sokulayisha okuphezulu.
◆ Abalandeli Abangafuneki: I-cooler ifakwe abalandeli abangafuneki kabili. Ifeni ngayinye inobubanzi obungu-400mm, ukugeleza komoya okuphezulu okungu-5000 m³/h, kanye nokusetshenziswa kwamandla okungu-150 W (ngesivinini esigcwele). Esimeni sokuhluleka kwefeni, iyunithi engasasebenzi isebenza phakathi kwamasekhondi angu-0.5, ivimbele ukuphazamiseka kokupholisa. Ukulawulwa kwesivinini - okuhlukile kulungisa isivinini sabalandeli ngokusekelwe kuzinzwa zezinga lokushisa, kunciphisa ukusetshenziswa kwamandla kufika ku-30% phakathi nezikhathi zokulayisha eziphansi -.
Isondlo Nokwethenjelwa
◆ Okushisayo - Izingxenye Ezishintshashintshayo: Abalandeli, izinzwa, nezingxenye ezincane zisekela ukushintshashintsha okushisayo -. Lokhu kusho ukuthi izingxenye zingashintshwa ngaphandle kokuvala isistimu yokupholisa, kuqinisekiswe ukusebenza kwesikhungo sedatha esingu-24/7. Ukumiselela abalandeli ngokugcwele kuthatha imizuzu engaphansi kweyi-10 ngamathuluzi ajwayelekile.
◆ Ukunakekela Okubikezelwayo: Kwakhelwe - ngezinzwa kuqapha isivinini sabalandeli, ukuhluka kwezinga lokushisa, nokudlidliza kwengxenye. Isistimu isebenzisa ama-algorithms aqhutshwa yi-AI - ukuze ibikezele ukwehluleka (isb., ukugqokwa kwefenisha, inzwa yokushayela) kufika emavikini angu-2 kusengaphambili. Izaziso zokunakekela zithunyelwa kusistimu yokuphatha isikhungo sedatha, okuvumela ukuhlela phakathi namahora angu-- aphakeme kakhulu (isb, ebusuku - ebusuku noma ngezimpelasonto).
Ukusebenza Kwamandla Nokusimama
◆ Ukusetshenziswa kwamandla: Ingqikithi yokusetshenziswa kwamandla epholile isukela ku-150 W (isiphephetha-moya ngasinye, isivinini esiphansi) kuya ku-300 W (ifeni ngalinye, isivinini esigcwele) ngemojula engu-50 kW. Ngokulawulwa kwesivinini - okuguquguqukayo, ukusetshenziswa kwamandla okumaphakathi kwehliswe ngo-30% uma kuqhathaniswa nezipholile zejubane - ezilungisiwe, okuhumushela ukonga unyaka nonyaka ka-$2,000–$5,000 module ngayinye (kusekelwe ku-0.15 $/kWh).
◆ Amanzi - Ukupholisa Kwamahhala: Ngokusebenzisa umoya we-ambient ukuze wenqabe ukushisa, isibandisi siqeda isidingo samasistimu asekelwe emanzini -. Lokhu kunciphisa ukusetshenziswa kwamanzi ngo-100% ukupholisa, ukuhambisana nezinjongo zokusimama kwezikhungo zedatha kanye nokunciphisa izindleko zokusebenza (akukho kuhlanza amanzi noma ukulungiswa kwamapayipi).
Isicelo & Ukuhambisana
◆ Izimo ze-Retrofit: Ilungele ukuthuthukisa izikhungo zedatha yefa. Idizayini ye-modular ilingana nezakhiwo zamarack ezikhona, futhi usayizi ohlangene (800mm × 1200mm × 1500mm module ngayinye) usebenza ezakhiweni ezihloselwe kabusha zezimboni noma inhloso - ezakhiweni ezakhiwe.
◆ Ukuvumelana: Ihlanganisa nengqalasizinda evamile yesikhungo sedatha (isb, i-Liebert, izinhlelo zokupholisa ze-Delta). Isekela kokubili umoya oqondile noma ongaqondile - wezakhiwo zokupholisa, ihlinzeka ngokuguquguquka kwezakhiwo ezihlukene zeseva.
Logistics & Delivery
◆ Ukupakishwa: Amamojula athunyelwa ngamakhreyithi enziwe ngokhuni (1200mm × 1000mm × 1800mm) ane-anti - yokudlidliza, eqinisekisa ukuhamba okuphephile.
◆ Isikhathi Sokulethwa: Isikhathi sokuhola esijwayelekile singamaviki angu-4-6 kuma-oda angokwezifiso. - ngamamojula esitoko (50 kW – 200 kW) ngomkhumbi lingakapheli iviki elingu-1.
◆ Ukufakwa: Ku-- ukufakwa kwesayithi kuthatha izinsuku ezingu-1–2 ngemojula ngayinye (okuhlanganisa izintambo nokuhlanganisa), ngokusekelwa okuvela eqenjini lobuchwepheshe lomkhiqizi.
Amashadi ashisayo: i-horizontal dry cooler, abakhiqizi baseChina abavundlile, abahlinzeki, imboni











